Combined Synopsis/Solicitation

150 HP ELECTRIC MOTOR

DEPT OF DEFENSE › DEPT OF THE ARMY › W6QM MICC-FT DRUM

Responses are due 2026-08-31, 10:00 (UTC−05:00).

View on SAM.gov →Official listing

Posted
2026-08-21
Response deadline
2026-08-31, 10:00 (UTC−05:00)
Set-aside
Small Business Set Aside - Total (SBA)
NAICS code
335312
Product/service code
6105
Place of performance
McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501, 74501

Description

Item: Electric motor Brand Name: Toshiba Part Number: B1504YLF4USH Salient Characteristics: Manufacturer Toshiba Model / Part Number B1504YLF4USHFrame Size NEMA 445T Enclosure Type Totally Enclosed Fan Cooled (TEFC) / Totally Enclosed Explosion Proof (TEXP) Mounting Configuration Footed Mount / Rigid Base Construction Material Rugged Cast Iron (Frame, End Brackets, Conduit Box, and Fan Cover) Physical Dimensions Height: ~26 in, Length: ~48.4 in, Width: ~22.4 in Estimated Net Weight ~2,087 lbs. . Electrical and Performance Characteristics These performance metrics ensure compatibility with tactical or base electrical systems . Salient Characteristic Required Specification Output Power 150 HP (Horsepower) Synchronous Speed 1800RPM (Revolutions Per Minute) Operating Voltage Dual-rated 230 / 460 VAC Phase /Frequency 3-Phase, 60 Hz Service Factor 1.15 Nominal Full Load Efficiency 95.8%(NEMA Premium Efficiency compliant) Full Load Amperage 352 A (at 230V) / 176 A (at460V) Duty Cycle Continuous .. Environmental and Safety Ratings Due to the critical nature of Department of War missions and operations in hazardous areas, the motor must carry verified explosion-proof ratings to handle volatile elements. Salient Characteristic Required Specification Hazardous Environment Certifications Must be certified for: Class I, Division 1, Group D (Flammable Gases) Class II, Division 1, Groups E, F and G(Combustible Dusts) Temperature Code Rating T3C (160C maximum exterior surface temperature under fault conditions) Standards Compliance Exceeds UL and CSA safety standards for hazardous environments1 each

Primary contact

David Fortune · [email protected] · 9184206445

Related link ↗

Every notice on this board links its official SAM.gov listing — verify details there before responding.

Run federal grants too?

Contract notices are free to browse and are not part of member fit-scoring, alerts, or the Tuesday digest — those cover grants. Members get every federal grant that opens fit-scored to their organization — with an alert when a real match posts.

See grants pricing

Get the free Tuesday grants digest

One email a week: the biggest new federal grants and what’s closing soon — the same list for everyone. Contract notices stay on this free board. Unsubscribe any time.

The free edition carries one clearly labeled sponsor slot. No spam, ever. Privacy

Want contract alerts?

Fit-scored alerts cover grants today; this contracts board is free to browse. If alerts for contract notices would help your team, say so below — enough interest is what gets them built.

Stored once, used only to tell you if contract alerts launch. No newsletter, no spam. Privacy