Solicitation

REPAIR LIVE FIRE TRAINING FACILITY AIRCRAFT MOCK-UP

DEPT OF DEFENSE › DEPT OF THE AIR FORCE › FA6656 910 AW LGC YNGSTN WRN ARPT

Responses are due 2026-09-21, 10:00 (UTC−04:00).

View on SAM.gov →Official listing

Posted
2026-08-27
Response deadline
2026-09-21, 10:00 (UTC−04:00)
Set-aside
SBA Certified Women-Owned Small Business (WOSB) Program Set-Aside (FAR 19.15) (WOSB)
NAICS code
236220
Product/service code
Z2BZ
Place of performance
Vienna, OH, 44473, USA

Description

The 910th Airlift Wing requires repair and corrective work to the Aircraft Fire Training Facility (AFTF) aircraft mock-up located at Youngstown Air Reserve Station. An inspection and evaluation of the Aircraft Fire Training Facility was conducted in August 2025 and finalized in April 2026. The assessment identified deficiencies affecting the facility's burner and ignition systems, structural components, corrosion protection, sprinkler system, propane distribution and emergency shutoff systems, control systems, and associated components. The contractor shall furnish all labor, supervision, materials, equipment, tools, transportation, testing, quality control, and other items and services necessary to complete the work identified in the Statement of Work, drawings, specifications, and solicitation attachments. Troubleshooting, repair, and/or replacement of the Tail Engine Burner, Wheel Well Burner, Flight Deck Burner, and Cargo Area Burner and associated ignition systems. Repair or replacement of burner ignition components as required to restore proper operation. Replacement of the malfunctioning cargo-area sprinkler head and restoration of proper drainage functionality. Structural steel repairs and corrosion remediation beneath portions of the aircraft mock-up. Corrosion repair beneath flight-deck stairs and around door assemblies. Repair and/or replacement of the warped R2 door and warped grating near the cargo-fire area. Certified welding and associated aircraft mock-up repairs. Installation/restoration of an emergency energy shutoff capability at the propane storage area. Installation of required solenoid valve(s) in the LPG/propane distribution system. Correction of deficiencies involving legacy pneumatic shutoff valves. Required control-system repairs/upgrades. Associated maintenance, testing, and corrective actions necessary to provide a complete and functional system. Applicable standards identified in the Government's technical documentation include, as applicable: USAF Technical Order 35E1-2-13-1 NFPA 54 NFPA 58 NFPA 70 NFPA 1003 NFPA 1402

Primary contact

Joseph Perry · [email protected] · 3306091212

Related link ↗

Every notice on this board links its official SAM.gov listing — verify details there before responding.

Run federal grants too?

Contract notices are free to browse and are not part of member fit-scoring, alerts, or the Tuesday digest — those cover grants. Members get every federal grant that opens fit-scored to their organization — with an alert when a real match posts.

See grants pricing

Get the free Tuesday grants digest

One email a week: the biggest new federal grants and what’s closing soon — the same list for everyone. Contract notices stay on this free board. Unsubscribe any time.

The free edition carries one clearly labeled sponsor slot. No spam, ever. Privacy

Want contract alerts?

Fit-scored alerts cover grants today; this contracts board is free to browse. If alerts for contract notices would help your team, say so below — enough interest is what gets them built.

Stored once, used only to tell you if contract alerts launch. No newsletter, no spam. Privacy